Fluke TI50FT-10/20/54 New

Fluke TI50FT-10/20/54

Fluke TI50FT-10/20/54 IR FlexCam Thermal Imager

Category Thermal Imagers
Description The Fluke Ti50FT10/20/54 IR Flexcam Thermal Imager, 320, S F/W, Fusion, 10.5/20/54MM is a great chose when you need the best images. They feature 320 x 240 detectors with industry leading thermal sensitivity (? 0.05 °C;50 mK NETD) for high resolution, ultra high-quality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display. Typical applications: Predictive maintenance – Identify electrical and mechanical problems before they cause failure Power/utilities – Real-time analysis of substations, transmission lines and equipment Process monitoring – Real-time observation to ensure efficient and safe operation Research and development – Quantify heat patterns to improve product designs Electronic design – Close up circuit board analysis The Fluke Ti50FT10/20/54 also includes: Heavy duty carrying case 2 rechargeable battery packs Battery charger AC adapter (for Ti55 model only) Video cable 512 MB compact flash card Compact flash card reader and USB cable Neck strap SmartView reporting and analysis software on CD User manual on CD Calibration certificate All FT models feature the innovative IR-Fusion® technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page. See exactly what you are viewing Fluke IR-Fusion® technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time. A sharp image in every situation The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring. Make anomalies visible Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies. Analysis and reporting comes standard The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page. Radiometric measurement – the ‘data behind the picture’ Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software.
Status New
Available Status Request Quote
Product Type
List Price 27130.00
  Our Price

Request a quote on this Fluke TI50FT-10/20/54. When you do, you tell us what you want to pay, and we'll do our best to match it.

Can't find what you want? Our inventory changes daily, so either check back frequently to find another used Fluke TI50FT-10/20/54, or drop us a line and we'll find it for you.

Looking to rent Fluke TI50FT-10/20/54 or other Thermal Imagers for rent?

Chances are we have it or we can find it for you. You only need to ask. Please use our request form to do so now. We'll give it immediate attention and get back to you as soon as possible.

Need repair or calibration?

Excalibur Engineering not only buys, sells, and rents new and used electronic test equipment, we also repair and calibrate used electronic test equipment - all under one roof.

Request Fluke TI50FT-10/20/54 repair
Read more and request Fluke TI50FT-10/20/54 calibration

Excalibur Engineering is your best source for new and used Fluke TI50FT-10/20/54 and other Thermal Imagers for sale or rent, repairs or calibration, at the BEST PRICE with the BEST WARRANTY. Request a quote today!

  • Field of view (FOV): 23° horizontal x 17° vertical Spatial resolution (IFOV): 1.30 mrad Min focus distance: 0.15 m (5.9 in) Thermal sensitivity (NETD): ? 0.07 °C at 30 °C (70mK) Detector data acquisition/ image frequency: 60 Hz/60 Hz Focus: SmartFocus; one finger continuous focus (manual) IR Digital Zoom: 2x Detector type: 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer Spectral band: 8 ?m to 14 ?m Digital image enhancement: Automatic full time enhanced On camera operating modes: Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture Visible light camera: 1280 x 1024 pixels, full color Visible light digital zoom: 2x Calibrated temperature range: -20 °C to 350 °C (-4 °F to 662 °F) in two ranges -- Range one = -20 °C to 100 °C (-4 °F to 212 °F) -- Range two = -20 °C to 350 °C (32 °F to 662 °F) Accuracy: ± 2 °C or 2 % (whichever is greater) Measurement modes: Centerpoint, center box (area min/max, average) Emissivity correction: 0.1 to 1.0 (0.01 increments) Digital display: 13 cm (5 in) diagonal large high-resolution digital display LCD backlight: Sunlight readable color LCD Video output: RS170 EIA/NTSC or CCIR/PAL composite video Palettes: Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted Optional 54 mm telephoto lens: High precision Germanium lens, Field of view (FOV): 9° horizontal x 6° vertical, Spatial resolution (IFOV): 0.47 mrad, Min focus distance: 0.6 m (1.97 ft) Optional 10.5 mm wide angle lens: High precision Germanium len, Field of view (FOV): 42° horizontal x 32° vertical, Spatial resolution (IFOV): 2.45 mrad, Min focus distance: 0.3 m (0.98 ft) Storage medium: Compact flash card stores over 1000 IR images (1 GB card standard) File formats supported: 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff; Data formats: comma separated (csv), tab separated (txt). Interface: Compact flash card reader included Software: SmartView; Full analysis and reporting software included Laser Classification: Class II Laser targeting: Laser dot visible on screen when blending thermal and visible image Set-up controls: Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) Image controls: Level, span, auto adjust (continuous/manual) On-screen indicators: Battery status, target emissivity, background temperature and realtime clock Battery type: Li-Ion smart battery, rechargeable, field-replaceable (two included) Battery operating time: Two hours continuous operation (per battery) Battery charging: Two bay intelligent charger powered via ac outlet Power saving: Automatic shutdown and sleep modes (user specified) Operating temperature: -10 °C to +50 °C (14 °F to 122 °F) Storage temperature: -40 °C to +70 °C (-40 °F to 158 °F) Relative humidity: Operating and storage 10 % to 95 %, non-condensing Water and dust resistant: IP54 Weight (including batteries): 1.95 kg (4.3 lb) Camera size (H x W x D): 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)  :  
Have you used this IR FlexCam Thermal Imager #TI50FT-10/20/54 by Fluke before?
Would you recommend it or not?

    No Reviews Found


We're veteran owned!

Veteran Owned Business Directory, Get your free listing, now!
      Why buy veteran-owned? 

Contact Excalibur

9201 Irvine Blvd.
Irvine, CA 92618
1-877-XCALIBR OR 877-922-5427
Phone: 949-454-6603
Fax: 949-454-6642
Email