Fluke Ti-50FT-10/20 New

Fluke Ti-50FT-10/20

Fluke Ti-50FT-10/20 IR FlexCam Thermal Imager

Category Thermal Imagers
Description See exactly what you are viewing Fluke IR-Fusion® technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time. Large, sharp thermal images Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments. A sharp image in every situation The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring. Make anomalies visible Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies. Analysis and reporting comes standard/span> The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page. Radiometric measurement – the ‘data behind the picture’ Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software. Ti55FT Ti50FT High resolution, low noise VOx detector for high quality images 320 x 240 Temperature range to cover broad industrial applications -20 to +600 ºC (-4 to 1112 ºF) -20 to +350 ºC(-4 to 662 ºF) High thermal sensitivity for viewing even the smallest temperature differences ?0.05 ºC ?0.07 ºC 180º articulating flexible lens to view images in every situation • • Choice of 3 interchangeable lenses to cover every application • • Large 5" high contrast color LCD for a clear picture independent of lighting conditions • • Fully radiometric for detailed temperature analysis and tracking • • SmartFocus for best image quality and accurate temperature measurements • • Windows® CE based menu structure for ease of use • • Personalized instrument set-up for multiple use • • CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data • • SmartView reporting and analysis software included • • AutoCapture for making intermittent problems visible • On-board analysis functions • User defined text annotations for simplified reporting • Built-in visible light (digital) camera • • IR/Visible Alarm function • Laser pointer for easy targeting • • Flash and torch light for high quality images in dark environments • • Keep your Thermal Imager at optimal performance! Check to see if you have the latest software or firmware version. Infrared Camera | Infrared Detector | Thermal Imager | Thermal Imaging | Infrared Digital Camera
Status New
Available Status Request Quote
Product Type
List Price 21830.00
  Our Price

Request a quote on this Fluke Ti-50FT-10/20. When you do, you tell us what you want to pay, and we'll do our best to match it.

Can't find what you want? Our inventory changes daily, so either check back frequently to find another used Fluke Ti-50FT-10/20, or drop us a line and we'll find it for you.

Looking to rent Fluke Ti-50FT-10/20 or other Thermal Imagers for rent?

Chances are we have it or we can find it for you. You only need to ask. Please use our request form to do so now. We'll give it immediate attention and get back to you as soon as possible.

Need repair or calibration?

Excalibur Engineering not only buys, sells, and rents new and used electronic test equipment, we also repair and calibrate used electronic test equipment - all under one roof.

Request Fluke Ti-50FT-10/20 repair
Read more and request Fluke Ti-50FT-10/20 calibration

Excalibur Engineering is your best source for new and used Fluke Ti-50FT-10/20 and other Thermal Imagers for sale or rent, repairs or calibration, at the BEST PRICE with the BEST WARRANTY. Request a quote today!

  • Specifications Temperature measurement Calibrated temperature range Ti55: -20 ?C to 600 ?C (-4 to 212 ºF) in 3 ranges Ti50: -20 ?C to 350 ?C (-4 to 662 ºF) in 2 ranges Range 1 Ti55: -20 ?C to 100 ?C (-4 to 212 ºF) Ti50: -20 ?C to 100 ?C (-4 to 212 ºF) Range 2 Ti55: -20 ?C to 350 ?C (-4 to 662 ºF Ti50: -20 ?C to 350 ?C (-4 to 662 ºF) Range 3 Ti55: 250 ?C to 600 ?C (482 to 1112 ºF) Accuracy ±2 °C or 2 % (whichever is greater) Measurement modes Ti55: Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below Ti50: Centerpoint, center box (area min/max, average) Emissivity correction 0.1 to 1.0 (0.01 increments) Imaging performance Thermal Field of view (FOV) 20 mm lens 23° x 17° FOV 10.5 mm lens 42° x 32° 54 mm lens 9° x 6 ° Spatial resolution (IFOV)* 1.30 mrad Thermal sensitivity (NETD) Ti55: ? 0.05 °C (50 mK)at 30 °C Ti50: ? 0.07 °C (70 mK) at 30 °C Detector data acquisition* 60 Hz Focus SmartFocus; one finger continuous focus IR digital zoom Ti55: 2x, 4x, 8x Ti50:2x Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer with 25 micron pitch Spectral band 8 µm to 14 µm Digital image enhancement Automatic full-time enhanced Visual On camera operating modes Full Thermal, full visual light or merged thermal-visual images. Picture-in-Picture Visible light camera 1280 x 1024 pixels, full color Visible light digital zoom Ti55: 2x, 4x Ti50: 2x Image presentation Digital display 5" large high-resolution digital display LCD backlight Sunlight readable color LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Optional lenses (Only available at time of purchase) 54 mm Telephoto lens High precision Germanium lens Field of view (FOV) 9 º horizontal x 6 º vertical Spatial resolution (IFOV) 0.47 mrad Min focus distance 0.6 m 10.5 mm wide angle lens High precision Germanium lens Field of view (FOV) 42 º horizontal x 32 º vertical Spatial resolution (IFOV) 2.45 mrad Min focus distance 0.3 m Image capture and data storage Storage medium Compact flash card stores over 1000 IR images (1 GB card standard) File formats supported 14 bit measurement data included. Exportable JPEG, BMP, PCX, PNG, PSD. Interfaces and software Interface Compact flash card reader included Software SmartView; Full analysis and reporting software included Laser Classification Class II Laser targeting Laser dot visible on screen when blending thermal and visible image Controls and adjustments Set-up controls Date/time, temperature units C/F/K, language, scale, LCD intensity (high/normal/low) Image controls Level, span, auto adjust (continuous/manual) On-screen indicators Battery status, target emissivity, background temperature and real time clock Set-up controls Date/time, temperature units C/F/K, language, scale, LCD intensity (high/normal/low) Power, battery life Battery type Li-Ion smart battery, rechargeable, field-replaceable Battery operating time 3 hours continuous operation (2 hours with IR-Fusion engaged) Battery charging 2 bay intelligent charger powered via AC outlet AC operation AC adapter 110/220 VAC, 50/60 Hz (Ti55 only) Power saving Automatic shutdown and sleep modes (user specified) Environmental and mechanical design Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -40 °C to +70 °C (-40 °F to 158 °F) Relative humidity Operating and storage 10 % to 95 %, non-condensing Water and dust resistant IP54 Weight (including batteries) 1.95 kg (4.3 lbs) Camera size (HxWxD) 162 x 262 x 101 mm (6.5" x 10.5" x 4.0") Other Warranty 2 years  :  
Have you used this IR FlexCam Thermal Imager #Ti-50FT-10/20 by Fluke before?
Would you recommend it or not?

    No Reviews Found


We're veteran owned!

Veteran Owned Business Directory, Get your free listing, now!
      Why buy veteran-owned? 

Contact Excalibur

9201 Irvine Blvd.
Irvine, CA 92618
1-877-XCALIBR OR 877-922-5427
Phone: 949-454-6603
Fax: 949-454-6642
Email