Test Equipment Sales, Rentals, Repairs and Calibration


 

4151
In stock


For Rental and Sales Quote:

Single Input Digital Thermometer, Measures J, K, T, and E-types of thermocouples, Relative time clock on MIN, MAX, and AVG provides a time reference for major events, 0.1 °C, 0.1 K < 1000, 1°C, 1 K >=1000 Display Resolution.

The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool. Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors).

Product Highlights

Fluke 50 Series II products features:

  • Relative time clock on MIN, MAX, and AVG provides a time reference for major events
  • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
  • Measures J, K, T, and E-types of thermocouples
  • Readout in ºC, ºF, or Kelvin (K)
  • Splash and dust resistant case protected by impact absorbing holster
  • User-friendly front panel is easy to set up and operate
  • Sleep mode increases battery life; typical 1000-hour battery life
  • Battery door allows easy battery replacement without breaking the calibration seal
  • Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation.
Specifications
Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C]1
  R and S-type: ±[0.05% + 0.4°C]1
Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C]1
  T-type: ±[0.50% + 0.3°C]
Temperature J-type -210°C to 1200°C
K-type -200°C to 1372°C
T-type -250°C to 400°C
E-type -150°C to 1000°C
N-type -200°C to 1300°C1
R and S-type 0°C to 1767°C1
Temperature scale ITS-90
Applicable standards NIST-175
Display resolution 0.1°C, 0.1 K < 1000
1°C, 1 K ≥ 1000
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.
Environmental Specifications
Operating temperature -10°C to 50°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 0% to 90%; 0°C to 35°C
0% to 70%; 0°C to 50°C
Safety Specifications
Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Agency approvals CE, CSA, TÜV (pending)
Mechanical and General Specifications
Size (L x W x D) 173 x 86 x 38 mm
Weight 400 g
Batteries 3 AA batteries; typical 1000-hour life